Multi Parameter Patient Monitors buy in Lancaster
Buy Multi Parameter Patient Monitors
Multi Parameter Patient Monitors

Multi Parameter Patient Monitors

In stock
Reconfirm the price with seller
Shipping:
Seller
United Kingdom, Lancaster
(View map)
+44( 
Display phones
Description

Product Details

Specifications

Main Spec. For the M1800 Multi Parameter Patient Monitor:

Product Description:

Standard parameter:

ECG, RESP, NIBP, SpO2, TEMP, PR Adopt independent modular design to resist vibration and electromagnetic interference Seven-lead ECG waveforms, Oxygen waveform and Respiratory waveform display on demand Apply to adults , children and newborn monitoring. 12. 1'' big screen true color TFT display , supporting external CRT Adopt digital SpO2 design to resist campaign interference and weak perfusion Protection against interference from defibrillation and electrosurgical knife 30 seconds ECG waveforms playback, Maximum 240 hours trend information saving and recalling Monitoring, diagnosis and surgery three models can be switched. Widely use in Medicine, surgery, operating theatres, ICU / CCU, obstetrics and gynecology, pediatrics, emergency department. Arrhythmia , ST section and ECG waveform anomaly can be detected. Build-in high-capacity battery , up to 4hours working time. Build-in printer.

Product Parameters

1. ECG Full Lead: I, Ⅱ, Ⅲ, AVL , AVR, AVF, V1, V2, V3, V4, V5, V6 Gain: 5 mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV Scanning Speed: Changeable with three grades of 12. 5mm/s, 25 mm/s, 50 mm/s Band width : 0. 05Hz-100Hz(3dB) Heart Rate: Scope : 15 times/minute to 300 times/minute Accuracy : ±1 time /minute Alarm: heart rate alarm: alarm delay < 12s

2. SpO2 Detection Scope : 1%-100% Resolution : 1% Accuracy: ±2% 80%-100%; ±3% 70%-79% Detection scope of pulse- rate: 30times minute to235 times/minute Pulse- rate Accuracy : ±2% within 30-235times/minute Arbitrary set the alarm ceiling and alarm limit

3. NIBP(Non-invasive blood pressure) Theory : Electric Oscillator Cuff gassing time : less than 15 seconds Adults and children model Detection Method: Automatic Detection cycle: 1minute to 240mintes Manual Detection at any time according to the needs of patients Detection Accuracy: Static pressure: 0. 5Kpa(±3mmHg) Protection: Inflatable overvoltage protection and Measurement protection Arbitrary set the alarm ceiling and alarm limit

 4. RESP (Respiration ) Detection Method : Chest Impedance Method Scope: 5times/minute-100times/minute Accuracy: ±2times/ minute (15times/minute-60times/minute) ±5times/minute (61times/minute-100times/minute) Alarm Preferences: Continuous-tuning step: 1time/minute Arbitrary set the alarm ceiling and alarm limit

 5. Temperature Channel: single or double path (T1, T2) Unit : ℃ or ℉ Scope: 25℃-45℃ Accuracy: ±0. 1℃ Resolution: 0. 1℃

6. Software Display Model: Large font model, tendency concurrent model, model with seven-lead on the same screen, standard model and complete model.

7. Print Taking paper speed: 25 mm/s Can print 1-3 any waveform at the same time